产品展示您现在的位置: 首页 > ac米兰app下载苹果 > > 美国戴安Dionex > 美国戴安 P/N: 078836Dionex IonPac CS19-4µm Column 阳离子交换柱

Dionex IonPac CS19-4µm Column 阳离子交换柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其*达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。

型号 美国戴安 P/N: 078836
厂商性质 代理商
更新日期 2018-04-16

Dionex IonPac CS19-4μm Cation-Exchange Column

High Resolution, High-Capacity Cation-Exchange Column for the Separation of Small Polar Amines

Attain the optimal combination of chromatographic speed and resolution using the new Thermo Scientific? Dionex? IonPac? CS19-4μm cation-exchange column. This high capacity, high resolution capillary column provides excellent resolution of common cations, small polar amines and polyvalent amines in complex sample matrices. Compared to the previous Dionex IonPac CS19 column, the new ion-exchange column uses smaller resin particles for more efficient separations resulting in faster analysis, more accurate peak integration, and more reliable results.

The Dionex IonPac CS19-4μm carboxylate-functionalized cation-exchange column has similar selectivity to the Dionex IonPac CS19 column for the six common cations, small polar amines (including alkanolamines and methylamines) and moderay hydrophobic and polyvalent amines (including biogenic amines and alkyl diamines). Applications run on the Dionex IonPac CS19 column can be easily transferred to the Dionex IonPac CS19-4μm column with the benefit of increased peak resolution which provides more consistent results. The Dionex IonPac CS19-4μm column is available in three formats, standard bore (4 × 250 mm), microbore (2 × 250 mm), and capillary  (0.4 × 250 mm). The capillary and microbore formats require less eluent thereby reducing operating costs.

  • Increase speed, chromatographic resolution and quality of analytical results
  • For analysis of amines including alkanolamines and methylamines in diverse sample matrices
  • For analysis of moderay-hydrophobic amines including biogenic amines, alkyl diamines, and polyvalent amines
  • Optimized for fast simple acidic gradient separations with minimal baseline shift
  • High capacity allows routine analysis of high-ionic-strength samples

The Dionex IonPac CS19-4μm column is targeted for analysis of power plant waters treated with ammonium, morpholine, or ethanolamine; as well as chemical additives; chemical process solutions; scrubber solutions; personal care products; and food samples.

The smaller resin particles used in the Dionex IonPac CS19-4μm column produce increased backpressure. When operating the Dionex IonPac CS19-4μm microbore or capillary column at standard flow rate, an IC system capable of operating up to 3000 psi is sufficient. However, to take advantage of the fast runs, using elevated flow rates, a high pressure IC system, such as the Thermo Scientific Dionex ICS-5000+ HPIC or Dionex ICS-4000 HPIC is required. The Dionex ICS-5000+ HPIC system is required for standard operation of the Dionex IonPac CS19-4μm standard bore column.

Thermo Scientific Dionex IonPac? CS19-4μm Cation-Exchange Column Specifications
Dimensions:Dionex IonPac CS19-4μm Analytical Column:
4 × 250 mm
Dionex IonPac CG19-4μm Guard Column:
4 × 50 mm
Dionex IonPac CS19-4μm Analytical Column:
2 × 250 mm
Dionex IonPac CG19-4μm Guard Column:
2 × 50 mm
Dionex IonPac CS19-4μm Capillary Column:
0.4 × 250 mm
Dionex IonPac CG19-4μm Capillary Guard Column:
0.4 × 50 mm
Maximum Operating Pressure:5000 psi (34 MPa)
Phase Compatibility:Acidic eluents, 0–10% HPLC solvents, excluding alcohols
Substrate Characteristics:Bead Diameter: 4 μm supermacroporous
Crosslinking (%DVB): 55%
Functional Group Characteristics:Ion-Exchange Group: Grafted carboxylic acid
Surface Characteristics: Medium hydrophobic
Capacity:2410 μeq (4 × 250 mm analytical column)
46 μeq (4 × 50 mm guard column)
600 μeq (2 × 250 mm analytical column)
11 μeq (2 × 50 mm guard column)
24 μeq (0.4 × 250 mm capillary column)
0.5 μeq (0.4 × 50 mm capillary guard column)
Column Construction:PEEK? with 10-32 threaded ferrule style end fittings.
All components are nonmetallic.
Analytical Columns
Dionex IonPac CS19-4μm Capillary Column (0.4 x 250 mm)078835
Dionex IonPac CS19-4μm Analytical Column (2 x 250 mm)078836
Dionex IonPac CS19-4μm Analytical Column (4 x 250 mm)078837
Guard Columns
Dionex IonPac CG19-4μm Capillary Guard Column (0.4 x 50 mm)078838
Dionex IonPac CG19-4μm Guard Column (2 x 50 mm)078839
Dionex IonPac CG19-4μm Guard Column (4 x 50 mm)078840