产品展示
PRODUCT DISPLAY

打印当前页

免费咨询:021-67610176

发邮件给我们:market@hsiyen.cn

分享到:
产品展示您现在的位置: 首页 > ac米兰app下载苹果 > > 美国戴安Dionex > 072927美国戴安Dionex Acclaim Carbamate LC Column 液相色谱柱

美国戴安Dionex Acclaim Carbamate LC Column 液相色谱柱

简要描述:

戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其*达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。   
戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。

型号 072927
厂商性质 代理商
更新日期 2017-10-25

美国戴安Dionex Acclaim Carbamate LC Column 液相色谱柱

Acclaim Carbamate LC Column 

The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

  • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
  • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
  • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
  • High efficiency, extremely low column bleed, and rugged column packing

Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

技术参数:


Acclaim Carbamate Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)6000 psi (4000 psi)
Operating pH range (recommended)2.5–8.0 (3.0–7.0)
Operating flow rate range (recommended)0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats
订购信息:

Analytical Columns
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm)075596
Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm)075597
Acclaim Carbamate, 5?m Analytical (4.6 x 250mm)072924
Acclaim Carbamate, 3?m Analytical (4.6 x 150mm)072925
Acclaim Carbamate, 3?m Analytical (3.0 x 150mm)072926
Acclaim Carbamate, 3?m Analytical (2.1 x 150mm)072927
Guard Columns
Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2)072928
Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2)072929
Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2)072930
Acclaim SST Guard Cartridge Holder V-2069580
Acclaim Guard Kit (Holder and coupler) V-2069707
Guard to Analytical Column Coupler V-2074188

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7