戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其*达80%。与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。 戴安公司的快速溶剂萃取仪15分钟之内仅用15毫升溶剂既可完成对10g样品的萃取,该技术已在环境、药物、食品和聚合物工业等领域得到广泛应用。
型号 | 064303 |
---|---|
厂商性质 | 代理商 |
更新日期 | 2017-10-27 |
美国戴安Dionex Acclaim Explosives LC Column 液相色谱柱
Acclaim Explosives Columns: A Total Solution for EPA Method 8330
The Thermo Scientific Acclaim™ Explosives E1 (5 ?m) and E2 (5, 3 and 2.2 μm) silica-based reversed-phase columns are designed to resolve all 14 explosives listed in EPA SW-846 Method 8330: Nitroaromatics and Nitramines by HPLC. Their unique chemistries deliver superior resolution with complementary selectivities. The E1 is recommended for use as a direct replacement for ODS columns for the primary analysis.The E2 may be used as either a primary or a confirmatory column.
The Acclaim Explosives stationary phases are based on ultrahigh-purity spherical silica gel particles, with 120 ? pore size. The Acclaim Explosives E1 is available in a 5 ?m particle size and E2 columns are available in 5, 3 and 2.2 μm particle sizes. The unique chemistry of these columns offers exceptional selectivity and stability over the range of pH 3.0 to 7.0, and their design ensures good column life and easy cleanup.
While both columns perform reproducibly under their optimized conditions, separation conditions for the Acclaim Explosives E2 can be readily changed to accommodate inclusion of additional explosives compounds.
The manufacturing process is controlled to ensure that every Explosives column delivers reproducible performance, lot-to-lot and column-to-column. The columns are tested for baseline resolution of all 14 explosives.
技术参数:
Acclaim Explosives Columns — A Total Solution for EPA Method 8330 Specifications | |
---|---|
Starting Material | Ultra-pure silica |
Particle Size | 3 ?m and 5 ?m |
Particle Shape | Spherical |
Particle Size Distribution (40/90) | < 1.3 |
Metal Impurity (Na, Fe, Al) | <10.0 ppm Total Metal < 3.0 ppm Individual Metals |
Pore Volume | 0.9 - 1.0 mL/g |
Average Pore Diameter | 120 ? |
Surface Area | 300 m2/g |
Recommended pH range | 3.0 - 7.0 |
Temperature Limit | 50 oC |
订购信息:
Analytical Columns | |
---|---|
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 100mm) | 076225 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (2.1 x 150mm) | 076226 |
Acclaim RSLC Explosives E2, 2.2?m Analytical (3.0 x 100mm) | 076227 |
Acclaim Explosive E2, 3 ?m, Analytical, (2.1 x 150 mm) | 070083 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 150 mm) | 070082 |
Acclaim Explosive E2, 3 ?m, Analytical, (3.0 x 250 mm) | 070081 |
Acclaim Explosives E1 (4.6 x 250 mm) | 064305 |
Acclaim Explosives E2 (4.6 x 250 mm) | 064309 |
Acclaim Explosives Kit (includes 064305, 064309, 064303, 064307; requires holder 059456) | 064312 |
Guard Columns | |
---|---|
Acclaim Explosives E1, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069702 |
Acclaim E2, 5?m Guard Cartridges (3 x 10mm), 2ea, requires holder 069580 | 071989 |
Acclaim Explosives E2, 5 ?m Guard Cartridges, (4.6 x 10 mm), 2 ea (use V-2 Holder) | 069703 |
Acclaim SST Guard Cartridge Holder V-2 | 069580 |
Acclaim Guard Kit (Holder and coupler) V-2 | 069707 |
Guard to Analytical Column Coupler V-2 | 074188 |
Acclaim Explosive E1 Guard (4.3 x 10 mm), 2 ea; requires holder 059456 | 064303 |
Acclaim Explosive E2 Guard (4.3 x 10 mm), 2ea; requires holder 059456 | 064307 |
Acclaim SST Guard Cartridge Holder V-1 | 059456 |
Guard to Analytical Column Coupler | 059457 |
Guard Kit (Holder and Coupler) | 059526 |